120 Ton ChillerCooling capacity: 420.0kWread more
Total power input: 131.0kW
Evaporator type: Stainless steel shell and tube type
Evaporator water side pressure: 16 bar
Water flow rate:... -
Mini Water ChillerCooling capacity: 1.6kWread more
Total power input: 0.9kW
Pump Power input: 0.25kW
Pump Head: 36m
Water flow rate: 0.28m³/h
Noise: 56db(A) -
10hp ChillerCooling capacity: 29.5kWread more
Total power input: 10.5kW
Pump Power input: 0.75kW
Pump Head: 27m
Water flow rate: 5.1m³/h
Noise: 65db(A) -
5hp ChillerCooling capacity: 15.0kWread more
Total power input: 5.3kW
Pump Power input: 0.55kW
Pump Head: 28m
Water flow rate: 2.6m³/h
Noise: 61db(A) -
5 Ton ChillerCooling capacity: 18.0kWread more
Total power input: 6.5kW
Pump Power input: 0.75kW
Pump Head: 33m
Water flow rate: 3.1m³/h
Noise: 62db(A) -
6 Ton ChillerCooling capacity: 23.0kWread more
Total power input: 8.4kW
Pump Power input: 0.75kW
Pump Head: 30m
Water flow rate: 4.0m³/h
Noise: 64db(A) -
10 Ton ChillerCooling capacity: 23.0kWread more
Total power input: 8.4kW
Pump Power input: 0.75kW
Pump Head: 30m
Water flow rate: 4.0m³/h
Noise: 64db(A) -
15 Ton ChillerCooling capacity: 44kWread more
Total power input: 15.0kW
Pump Power input: 1.2kW
Pump Head: 27m
Water flow rate: 7.6m³/h
Noise: 66db(A) -
20 Ton ChillerCooling capacity: 69.0kWread more
Total power input: 24.0kW
Pump Power input: 2.2kW
Pump Head: 26m
Water flow rate: 11.8m³/h
Noise: 68db(A) -
25 Ton ChillerCooling capacity: 86.0kWread more
Total power input: 30.0kW
Pump Power input: 2.2kW
Pump Head: 25m
Water flow rate: 14.8m³/h
Noise: 68db(A) -
30 Ton ChillerCooling capacity: 86.0kWread more
Total power input: 30.0kW
Pump Power input: 2.2kW
Pump Head: 25m
Water flow rate: 14.8m³/h
Noise: 68db(A) -
100 Ton ChillerCooling capacity: 350.0kWread more
Total power input: 109.0kW
Evaporator type: Stainless steel shell and tube type
Evaporator water side pressure: 16 bar
Water flow rate:...
A glycol chiller is a chilling system that uses a percentage of glycol mixed with water to create extremely low temperatures far beyond the freezing point of water. The two types of glycol are...
Nov 09, 2020 · Glycol Cooling Systems. In cooling systems, the primary purpose of glycol is to help the system stay as consistently cold as...
Glycol Cooling Systems - HVAC Designs. Inc. installs, designs and maintains glycol cooling systems found in computer server rooms, breweries, wineries, food processing and many other areas where...
Understanding if Glycol Fits Your Needs: A glycol chiller is the right solution if you’re using a long-draw system. This means that you would like to have your chiller at least 75’ away from...
Ammonia is cheap and extremely efficient. Ammonia is the most commonly used refrigerant worldwide for large commercial applications. The main use of ammonia is agricultural (fertilizer). More than 80...
An ambient temperature of -20° F would be attainable with a 45% glycol level. An ambient temperature of -50° F would be attainable with a 55% glycol level. In summary, the lower...